Stainless steel manufactured to ASTM: A 240/A 240M – 95a designation S31603 or EN 10088 grade 1 – 4404 with a post treatment (b)įor materials which have no declared corrosion resistance classification Stainless steel manufactured to ASTM: A 240/A 240M – 95a designation S30400 or EN 10088 grade 1 – 4301 with a post treatment (b) Stainless steel manufactured to ASTM: A 240/A 240M – 95a designation S31603 or EN 10088 grade 1 – 4404 without a post treatment (b) Stainless steel manufactured to ASTM: A 240/A 240M – 95a designation S30400 or EN 10088 grade 1 – 4301 without a post treatment (b) Post – galvanised to a zinc mean coating thickness (minimum) of 85 m according to BS EN ISO 1461 for zinc thickness only Post – galvanised to a zinc mean coating thickness (minimum) of 70 m according to BS EN ISO 1461 for zinc thickness only Post – galvanised to a zinc mean coating thickness (minimum) of 55 m according to BS EN ISO 1461 for zinc thickness only Post – galvanised to a zinc mean coating thickness (minimum) of 45 m according to BS EN ISO 1461 for zinc thickness only Pre – galvanised to grade 350 to BS EN 10346 Pre – galvanised to grade 275 to BS EN 10346 and follow the relevant specification in Table 8, with compliance according to Table 7.) Table 1 – classification for resistance against corrosion ClassĮlectroplated to a minimum thickness of 5 mĮlectroplated to a minimum thickness of 12 m (Resistance to corrosion is classified according to Table 1. Information relating to compliance is detailed/highlighted within the following sections of the standard: 6 Classification 6.1 According to materialĦ.1.1 Metsec cable ladder systems are metallic system components 6.2 According to resistance to flame propagationĦ.6.2 Metsec cable ladder systems are non – flame propagating system components 6.3 According to electrical continuity characteristicsĦ.3.2 Metsec cable ladder systems have electrical continuity characteristics 6.4 According to electrical conductivityĦ.4.1 Metsec cable ladder systems are electrically conductive system components 6.5 According to resistance against corrosionĦ.5.2 Metsec cable ladder systems are made of steel with metallic finishes or stainless steel Voestalpine Metsec Cable Ladder Systems generally conform to BS EN 61537 Cable management – cable tray systems and cable ladder systems Purlins & Side Rails Contact our Purlins & Siderails Team Purlins & Side Rails.With a wide variety of sizes, mounting systems and accessories, the system can be adapted to any electrical installation.Įurostrut supplies Pemsaband One from stock with an HDG (hot dip galvanized) finish. The embedded perforations ensure a lower own weight, but increase the transverse and longitudinal strength and thus also the carrying capacity. Pemsaband One cable trays are provided with a safety edge, because the risk of damage to material and mechanic is reduced to a minimum. Depending on the need, a gutter height of 35, 60 or 100 mm can be chosen in a variety of widths. Thanks to the smart click system, these cable trays are easy to install. The Pemsaband One perforated cable tray is suitable for supporting and guiding electrical cables of medium and light loads. Our brandsĮurostrut supplies cable trays of the brands Pemsa (Pemsaband One, soon online), Vergokan and NATO. Cable trays are used for support, management and distribution of cables in electrical and/or telecommunications installations in civil works, tunnels, parking garages, public buildings, shopping malls, data centers, infrastructures, airports and railways.ĭepending on the surface treatment, cable trays can be used in demanding and corrosion-sensitive industries and environments.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |